Part # | VI | Input Type | PI | VO | PO | IOP | VOS | IOS | Volt Reg. | Ripple | Line Reg. | Stability | Control Type | Control Voltage | Control Range | Op. Temp. | TCOEFF | Store Temp. | Humidity | Altitude |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
V | W | V | W | mA | V | -A | % VDC | % VPP | % VDC | % VDC | VDC | % VO | °C | % / °C | °C | % | Ft. | |||
Air Cleaner Subseries | ||||||||||||||||||||
SPL-A-AC-15N50 | 108 - 264 | AC | 65 | -15000 | 50 | 3.4 | -7500 | 300 | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-A-DC-15N50 | 21 - 28 | DC | 65 | -15000 | 50 | 3.4 | -7500 | 300 | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-A-AC-15P50 | 108 - 264 | AC | 65 | 15000 | 50 | 3.4 | 7500 | 300 | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-A-DC-15P50 | 21 - 28 | DC | 65 | 15000 | 50 | 3.4 | 7500 | 300 | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
Industrial Subseries | ||||||||||||||||||||
SPL-I-AC-30N50 | 108 - 264 | AC | 65 | -30000 | 50 | 1.7 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-I-DC-30N50 | 21 - 28 | DC | 65 | -30000 | 50 | 1.7 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-I-AC-15N50 | 108 - 264 | AC | 65 | -15000 | 50 | 3.4 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-I-DC-15N50 | 21 - 28 | DC | 65 | -15000 | 50 | 3.4 | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 | |
SPL-I-AC-15P50 | 108 - 264 | AC | 65 | 15000 | 50 | 3.4 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-I-DC-15P50 | 21 - 28 | DC | 65 | 15000 | 50 | 3.4 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-I-AC-30P50 | 108 - 264 | AC | 65 | 30000 | 50 | 1.7 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |
SPL-I-DC-30P50 | 21 - 28 | DC | 65 | 30000 | 50 | 1.7 | - | - | < 0.2 | < 3 | < 0.1 | < 0.2 | Analog Signal | 0 - 5 | 50 - 100 | 0 to 60 | 0.05 | -40 to 85 | 0 to 95 | 0 to 10000 |